WELCOME TO THE OFFICIAL WEBSITE OF HUIZHOU HICOOL CLIMATE EQUIPMENT CO., LTD

0752-5313400

CONSULTING HOTLINE

PRODUCTS

NEWS

CONTACT

TELEPHONE:0752-5313400(Home Sales), 5313858(Oversea Sales)

MOBILEPHONE:13502293103(Mr. Lei,Home Sales),13600105055(Mr. Li,Oversea Sales)

FAX:0752-5313133

Packaged Floor StandIng Water Source Heat Pump

CURRENT POSITION: HOME  > ABOUT HEZHIBAO > Packaged Floor StandIng Water Source Heat Pump


Water Source Heat Pump Units

Products in detail


Performance characteristics

     1. High efficiency and energy saving, saving investment

     Water loop heat pump units with higher efficiency than air-cooled heat pump units. In need of cooling and heating at the same time, it is possible to realize the internal energy balance system, reduce the running time of cooling tower and heating equipment, to achieve energy saving purpose. At the same time, compared with the traditional central air conditioning, water loop heat pump systems without special room, also do not need big ventilation pipe.

     2. Easy installation, flexible application

     Design and installation is simple, less control device, waterway configuration is simple, short design cycle. At the same time, the user can choose according to different conditions of use refrigeration or heating, heating or cooling part.

     3. Separate metering

     Can be connected to the electric meter user's single, easy to separate measuring air conditioning electricity, electricity metering disputes.

     4. The fresh air into, improve air quality

     System, fresh air can be introduced from air-condition disease trouble.

Scope of application

     Can be widely used in office buildings, apartments, hotels, Banks, schools and gyms and other places.

Parameter

     Parameter List of Water Source Heat Pump Units

Model No

H-WFs180

H-WFs500

H-WFs900

H-WFs1500

H-WFs1750

Performance

Cooling capacity

KW

18

50

90

152

175

Heating capacity

KW

19

52.5

94.5

159.6

184

rated air flow

CMH

3500

8000

15300

25500

28600

static pressure outside of unit

Pa

120

150

300

400

400

Power supply

3PH 380V 50Hz

Running power

KW

4.4

13

22.3

37.1

42.7

Running current

A

8.9

26.6

44.5

70.2

83.5

Noise level

dB(A)

62

68

73

76

78

Compressor

Type

Scroll type

Qty

1

2

3

4

4

Power

KW

3.8

11.4

18.3

29.6

34.3

Fan

Type

Centrifugal fan

Qty

1

2

2

2

2

Power

KW

0.7

1.6

4

7.5

9.2

Refrigerant

R410A

Water flow

M³/h

4.4

10.5

19

31.2

38.4

Water pressure drop

Kpa

59

60

83

112

125

Protections

High/low pressure protection, compressor overload protection, sequence protection, starting delay protection, oil heater, water flow protection, overthermo protection, etc.

Dimension

W

mm

1100

1600

1880

2450

2450

L

mm

660

800

1010

1300

1300

H

mm

1730

1730

1810

1990

1990

Packing Dimension

W

mm

1180

1680

1940

2500

2500

L

mm

740

880

1090

1380

1380

H

mm

1810

1810

1860

2050

2050

Net weight

Kg

310

480

890

1560

1660

Gross weight

Kg

325

500

920

1610

1750

Note : 1. Nominal Cooling Condition:indoor dry bulb is 27℃,indoor wet bulb is 19℃;cooling input water temperature is         30℃,cooling output water temperature is 35℃.

          2. Nominal Heating Condition:indoor dry bulb is 20℃,indoor wet bulb is 15℃;cooling input water temperature is         20℃,cooling output water temperature is 15℃.

Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving

Performance characteristics

    1. High efficiency and energy saving, saving investment

   Water loop heat pump units with higher efficiency than air-cooled heat pump units. In need of cooling and heating at the same time, it is possible to realize the internal energy balance system, reduce the running time of cooling tower and heating equipment, to achieve energy saving purpose. At the same time, compared with the traditional central air conditioning, water loop heat pump systems without special room, also do not need big ventilation pipe.
    2. Easy installation, flexible application
    Design and installation is simple, less control device, waterway configuration is simple, short design cycle. At the same time, the user can choose according to different conditions of use refrigeration or heating, heating or cooling part.
    3. Separate metering
    Can be connected to the electric meter user's single, easy to separate measuring air conditioning electricity, electricity metering disputes.
    4. The fresh air into, improve air quality

    System, fresh air can be introduced from air-condition disease trouble.

Scope of application

    Can be widely used in office buildings, apartments, hotels, Banks, schools and gyms and other places.

Parameter

    Parameter List of Water Source Heat Pump Units

Note : 1. Nominal Cooling Condition:indoor dry bulb is 27℃,indoor wet bulb is 19℃;cooling input water temperature is 30℃,cooling output water temperature is 35℃.

         2. Nominal Heating Condition:indoor dry bulb is 20℃,indoor wet bulb is 15℃;cooling input water temperature is 20℃,cooling output water temperature is 15℃.

Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving
PRODUCT | TECHNOLOGY | ASSURANCE | SOLUTIONS | PROJECT CASE
CONSULT
QQ
OFFICIAL

RichScan
Thank you for your attention!

HICOOL

RichScan
Learn more!

TOP