Terminals - High Efficiency & Energy-saving Fresh Air Exchange Unit

Products in detail


Performance characteristics

    1. box

     The combination of low thermal resistance and high sealing wall Aluminum Alloy profile with color steel plate made from polyurethane foam panel for the whole, the coefficient of thermal conductivity is: =0.022w/m. C, also can use high vinyl siding or glass wool panel, the structure has the best performance in all aspects of thermal insulation, sound insulation, fire prevention, strength and service life and cleanliness. A strict selection unit so that the machine has rust corrosion resistant, beautiful and durable, the advantage of small box design and air leakage rate; flexible production is flexible, easy for customers to make the most effective use of personality and building space.

    2. fans

     The outer rotor centrifugal fan, and the static balance and dynamic balance and dynamic balance test strictly, ensure the operation of low noise, high efficiency, strong structure, stable performance, many specifications of the series products can be used widely on different occasions to meet the requirements of a wide range of air volume and pressure.

    3. meter cooler

     The cooler body adopts the high quality seamless copper and high purity aluminum foil, with advanced mechanical or hydraulic expansion pipe process to close one after 2.8MPa pressure seal leakage test, the performance of the United States ARI standards, to ensure the products with superior performance and reliable quality.

    4. dry condensate tray

     The water tray adopts unique integral big slope dry antibacterial structure and super thick lining thermal insulation material, and ensures that the unit has no dew dripping in abominable environment. The setting of the condensed disc is favorable to the discharge of condensed water. At the same time, the condensate pipe is calculated according to the non full flow state, and the emission capacity is more than 5 times that of the unit during normal operation. The timely discharge of condensed water not only reduces the corrosion of the condensate tray, but also effectively inhibits the retention of sewage and the growth of bacteria, and ensures the indoor air quality.

    5. air filter

     Standard filter unit equipment for the type of filter (nylon mesh / aluminum mesh / non-woven), interception efficiency is more than 65%. The utility model has the advantages of firm structure, long service life and repeated cleaning. All filters are mounted on standard chutes for easy inspection and replacement. In accordance with the special requirements of users, but also to provide a higher efficiency of filtering a wide range of filters in various grades of high efficiency. Optional voltage differential meter, reserved signal interface.

    6. tuyere

     With the jet ball with superior jet performance as the air outlet, long distance air supply can be realized without air pipe. Particularly suitable for large space, such as: concert halls, theaters, museums, especially for large areas of the workshop under the warm air delivery, the application is very convenient. When the horizontal air supply, the air supply angle can be manually or within 60 degrees, and the controller can be adjusted up and down so that the cold and hot air can be delivered to the required position.

    7. control

     Optional with the company's design and manufacture of variable frequency speed regulation system, according to air conditioning load, automatically adjust the air conditioning unit to send air volume, transition season can adopt new air operation.

Scope of application

     1. spaces, hoping to reduce one-time investment and save air conditioning operating costs;

     2. indoor upper space is not allowed to install the wind pipe occasions;

     3. large space hot air difficult to send the following occasions. For example: large supermarkets, factories, workshops, stadiums, swimming pool, waiting hall, exhibition hall, lobby, lobby and so on.

Parameter 

      Parameter List of Terminals - High Efficiency & Energy-saving Fresh Air Exchange Unit

 

   Paramete

 

  Model

Air flow m³/h

Excess PressurePa

Cooling CapacityKW

Heating CapacityKW

Power (KW)

Noise dBA)

Weight (Kg)

Ruturn Air Conditon

Fresh Air Conditon

Ruturn Air Conditon

Fresh Air Conditon

HYS-12

1200

180

7.1

13.0

11.6

21.5

0.25

54

80

HYS-25

2500

220

15.0

26.7

24.1

45.6

0.45

57

129

HYS-40

4000

200

24.2

42.3

38.4

73.3

0.37×2

58

166

HYS-50

5000

220

30.1

53.4

48.2

91.6

0.45×2

59

183

HYS-60

6000

230

36.2

64.6

58.0

110.2

0.55×2

60

196

HYS-70

7000

280

41.3

72.4

68.5

126.8

0.75×2

61

208

HYS-80

8000

300

47.1

82.7

78.3

148.6

0.75×2

61

232

HYS-90

9000

360

54.4

96.2

86.6

163.8

1.1×2

62

246

HYS-100

10000

500

60.3

106.7

96.3

182.5

1.5×2

63

268

HYS-120

12000

500

72.4

129.2

116

220.5

1.8×2

64

289

 

Paramete

 

Model

Air flow m³/h

Excess Pressure Pa

Water Flow
 
Kg/h)

Water Asistancce
( Kpa)

Power (KW)

Noise dBA)

Weight (Kg)

Ruturn Air Conditon

Fresh Air Conditon

Ruturn Air Conditon

Fresh Air Conditon

HYS-12

1200

180

1.23

2.2

2.1

4.1

0.25

54

80

HYS-25

2500

220

2.58

4.59

3.5

6.4

0.45

57

129

HYS-40

4000

200

4.16

7.34

9.4

17.5

0.37×2

58

166

HYS-50

5000

220

5.17

9.12

11.5

21.4

0.45×2

59

183

HYS-60

6000

230

6.22

111

14.5

28.4

0.55×2

60

196

HYS-70

7000

280

7.26

12.9

16.2

26.4

0.75×2

61

208

HYS-80

8000

300

8.3

17.8

18.4

28.1

0.75×2

61

232

HYS-90

9000

360

9.33

16.5

19.4

32.7

1.1×2

62

246

HYS-100

10000

500

10.3

18.3

21.4

38.4

1.5×2

63

268

HYS-120

12000

500

13.8

22.1

24.6

42.1

1.8×2

64

289

Note: 1. Reture air condition:Supply cooling air inlet dry bulb 27℃,wet dulb 19.5℃,water inlet7℃.water in-out temperature difference5℃.

         2. Fresh air condition:Supply cooling air inlet dry bulb 34℃,wet dulb 28℃,water inlet7℃.water in-out temperature 

difference5℃.

         3. Supply heating air inlet dry buld -4℃,hot water inlet temperature60℃.

Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving

Performance characteristics
  1. box
  The combination of low thermal resistance and high sealing wall Aluminum Alloy profile with color steel plate made from polyurethane foam panel for the whole, the coefficient of thermal conductivity is: =0.022w/m. C, also can use high vinyl siding or glass wool panel, the structure has the best performance in all aspects of thermal insulation, sound insulation, fire prevention, strength and service life and cleanliness. A strict selection unit so that the machine has rust corrosion resistant, beautiful and durable, the advantage of small box design and air leakage rate; flexible production is flexible, easy for customers to make the most effective use of personality and building space.
  2. fans
  The outer rotor centrifugal fan, and the static balance and dynamic balance and dynamic balance test strictly, ensure the operation of low noise, high efficiency, strong structure, stable performance, many specifications of the series products can be used widely on different occasions to meet the requirements of a wide range of air volume and pressure.
  3. meter cooler
  The cooler body adopts the high quality seamless copper and high purity aluminum foil, with advanced mechanical or hydraulic expansion pipe process to close one after 2.8MPa pressure seal leakage test, the performance of the United States ARI standards, to ensure the products with superior performance and reliable quality.
  4. dry condensate tray
  The water tray adopts unique integral big slope dry antibacterial structure and super thick lining thermal insulation material, and ensures that the unit has no dew dripping in abominable environment. The setting of the condensed disc is favorable to the discharge of condensed water. At the same time, the condensate pipe is calculated according to the non full flow state, and the emission capacity is more than 5 times that of the unit during normal operation. The timely discharge of condensed water not only reduces the corrosion of the condensate tray, but also effectively inhibits the retention of sewage and the growth of bacteria, and ensures the indoor air quality.
  5. air filter
  Standard filter unit equipment for the type of filter (nylon mesh / aluminum mesh / non-woven), interception efficiency is more than 65%. The utility model has the advantages of firm structure, long service life and repeated cleaning. All filters are mounted on standard chutes for easy inspection and replacement. In accordance with the special requirements of users, but also to provide a higher efficiency of filtering a wide range of filters in various grades of high efficiency. Optional voltage differential meter, reserved signal interface.
  6. tuyere
  With the jet ball with superior jet performance as the air outlet, long distance air supply can be realized without air pipe. Particularly suitable for large space, such as: concert halls, theaters, museums, especially for large areas of the workshop under the warm air delivery, the application is very convenient. When the horizontal air supply, the air supply angle can be manually or within 60 degrees, and the controller can be adjusted up and down so that the cold and hot air can be delivered to the required position.
  7. control

   Optional with the company's design and manufacture of variable frequency speed regulation system, according to air conditioning load, automatically adjust the air conditioning unit to send air volume, transition season can adopt new air operation.

Scope of application
    1. spaces, hoping to reduce one-time investment and save air conditioning operating costs;
    2. indoor upper space is not allowed to install the wind pipe occasions;

    3., large space hot air difficult to send the following occasions. For example: large supermarkets, factories, workshops, stadiums, swimming pool, waiting hall, exhibition hall, lobby, lobby and so on.

Parameter 

    Parameter List of Terminals - High Efficiency & Energy-saving Fresh Air Exchange Unit

Note: 1. Reture air condition:Supply cooling air inlet dry bulb 27℃,wet dulb 19.5℃,water inlet7℃.water in-out temperature difference5℃.

         2. Fresh air condition:Supply cooling air inlet dry bulb 34℃,wet dulb 28℃,water inlet7℃.water in-out temperature 

difference5℃.

         3. Supply heating air inlet dry buld -4℃,hot water inlet temperature60℃.

Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving

PRODUCT | TECHNOLOGY | ASSURANCE | SOLUTIONS | PROJECT CASE
CONSULT
QQ
OFFICIAL

RichScan
Thank you for your attention!

HICOOL

RichScan
Learn more!

TOP