Small Air Cooled Chiller Unit

CURRENT POSITION: HOME  > ABOUT HEZHIBAO > Small Air Cooled Chiller Unit


Small Wind Cold Hot Water Unit

Products in detail


Small Air Cooled Chiller Unit

Specifications

   Small air cooled chiller unit 

   Separate structure 

   Quiet operation 

   Easy installation 

   Automatic control 

   Small air cooled chiller unit

   Energy-saving, air-cooled heat pump system units are an economical way to provide a reliable supply of hot and cold water. Highly efficient and compact since no cooling tower is required, they are also suitable for office building air-conditioning. These high-end models provide an answer to a variety of air-conditioning requirements.

Feature

   Separate structure: Each type has complete models. 

   Quiet operation: Low-noise vortex compressor and low-speed cooling fan enabling quiet operation of the entire unit. 

   Easy installation: Factory completed internal wiring and refrigerant filling, and ex-factory strict testing; ready to use in the site once the power is switched on and the cooling water pipe connected.

   Automatic control: The control cabinet containing all basic electric protection

devices, including electromagnetic switch, relay, over-current protector, and etc.

Parameter 

   Parameter List of Small Wind Cold Hot Water Unit

 Model

H-AchR105S/P

H-AchR150S/P3

H-AchR200S/P3

H-AchR250S/P3

H-AchR300S/P3

 Cooling Capacity

kW

10.5

15

20

25

30

 Heating Capacity

kW

11.7

16.6

22.2

27.8

33.2

Rated Input Power

Cooling

kW

3.5

4.9

6.5

8.2

9.8

Heating

kW

3.7

5.3

6.9

8.6

10.5

 Power Supply

220V/1P/50Hz

380V/3P/50Hz

Compressor Quantity

Sets

1

1

2

2

2

Fan Quantity

Sets

1

1

2

2

2

 Refrigerant

R410A

 Ambient Temperature

-15℃~-43

 Control Manner

Central control and network control

 Protection

High/low pressure protection, freezing-proof protection, over-current protection, water-break protection

 Noise

dB(A)

57

58

59

60

60

 Pump

Water Head

m

15

20

20

20

20

Water Flow

m³/h

1.8

2.6

3.44

4.3

5.2

 Water Gap Spec

inches

1"

1"

1-1/4"

1-1/2"

1-1/2"

Net Dimension(LxWxH)

mm

1006×460×1445

1006×460×1445

1362×483×1553

1362×483×1553

1362×483×1553

 Net Weight

kg

118

127

210

222

230

Packing Dimension(LxWxH)

mm

1130×630×1620

1130×630×1620

1520×670×1740

1520×670×1740

1520×670×1740

Gross Weight

kg

128

137

233

245

265



Note : 1. Nominal cooling conditions: condenser air inlet dry bulb temperature: 35℃, wet bulb temperature: 24℃, evaporator water inlet temperature: 12℃, water outlet temperature: 7℃


          2. Nominal heatling conditions: outdoor dry bulb temperature: 7℃, wet bulb temperature: 6℃, evaporator water inlet temperature: 40℃, water outlet temperature: 45℃

Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving


Small Air Cooled Chiller Unit

Specifications

   Small air cooled chiller unit 

   Separate structure 

   Quiet operation 

   Easy installation 

   Automatic control 

   Small air cooled chiller unit

   Energy-saving, air-cooled heat pump system units are an economical way to provide a reliable supply of hot and cold water. Highly efficient and compact since no cooling tower is required, they are also suitable for office building air-conditioning. These high-end models provide an answer to a variety of air-conditioning requirements.

Feature

   Separate structure: Each type has complete models. 

   Quiet operation: Low-noise vortex compressor and low-speed cooling fan enabling quiet operation of the entire unit. 

   Easy installation: Factory completed internal wiring and refrigerant filling, and ex-factory strict testing; ready to use in the site once the power is switched on and the cooling water pipe connected.

   Automatic control: The control cabinet containing all basic electric protection

devices, including electromagnetic switch, relay, over-current protector, and etc.

Parameter 

   Parameter List of Small Wind Cold Hot Water Unit


Note : 1. Nominal cooling conditions: condenser air inlet dry bulb temperature: 35℃, wet bulb temperature: 24℃, evaporator water inlet temperature: 12℃, water outlet temperature: 7℃

          2. Nominal heatling conditions: outdoor dry bulb temperature: 7℃, wet bulb temperature: 6℃, evaporator water inlet temperature: 40℃, water outlet temperature: 45℃