WELCOME TO THE OFFICIAL WEBSITE OF HUIZHOU HICOOL CLIMATE EQUIPMENT CO., LTD
PRODUCTS
NEWS
CONTACT
TELEPHONE:0752-5313400(Home Sales), 5313858(Oversea Sales)
MOBILEPHONE:13502293103(Mr. Lei,Home Sales),13600105055(Mr. Li,Oversea Sales)
FAX:0752-5313133
Total product classification
Small Air Cooled Chiller Unit
CURRENT POSITION: HOME > ABOUT HEZHIBAO > Small Air Cooled Chiller Unit
Products in detail
Small Air Cooled Chiller Unit
Specifications
Small air cooled chiller unit
Separate structure
Quiet operation
Easy installation
Automatic control
Small air cooled chiller unit
Energy-saving, air-cooled heat pump system units are an economical way to provide a reliable supply of hot and cold water. Highly efficient and compact since no cooling tower is required, they are also suitable for office building air-conditioning. These high-end models provide an answer to a variety of air-conditioning requirements.
Feature
Separate structure: Each type has complete models.
Quiet operation: Low-noise vortex compressor and low-speed cooling fan enabling quiet operation of the entire unit.
Easy installation: Factory completed internal wiring and refrigerant filling, and ex-factory strict testing; ready to use in the site once the power is switched on and the cooling water pipe connected.
Automatic control: The control cabinet containing all basic electric protection
devices, including electromagnetic switch, relay, over-current protector, and etc.
Parameter
Parameter List of Small Wind Cold Hot Water Unit
Model
H-AchR105S/P
H-AchR150S/P3
H-AchR200S/P3
H-AchR250S/P3
H-AchR300S/P3
Cooling Capacity
kW
10.5
15
20
25
30
Heating Capacity
kW
11.7
16.6
22.2
27.8
33.2
Rated Input Power
Cooling
kW
3.5
4.9
6.5
8.2
9.8
Heating
kW
3.7
5.3
6.9
8.6
10.5
Power Supply
220V/1P/50Hz
380V/3P/50Hz
Compressor Quantity
Sets
1
1
2
2
2
Fan Quantity
Sets
1
1
2
2
2
Refrigerant
R410A
Ambient Temperature
-15℃~-43℃
Control Manner
Central control and network control
Protection
High/low pressure protection, freezing-proof
protection, over-current protection, water-break protection
Noise
dB(A)
57
58
59
60
60
Pump
Water Head
m
15
20
20
20
20
Water Flow
m³/h
1.8
2.6
3.44
4.3
5.2
Water Gap Spec
inches
1"
1"
1-1/4"
1-1/2"
1-1/2"
Net Dimension(LxWxH)
mm
1006×460×1445
1006×460×1445
1362×483×1553
1362×483×1553
1362×483×1553
Net Weight
kg
118
127
210
222
230
Packing Dimension(LxWxH)
mm
1130×630×1620
1130×630×1620
1520×670×1740
1520×670×1740
1520×670×1740
Gross Weight
kg
128
137
233
245
265
Note : 1. Nominal cooling conditions: condenser air inlet dry bulb temperature: 35℃, wet bulb temperature: 24℃, evaporator water inlet temperature: 12℃, water outlet temperature: 7℃
2. Nominal heatling conditions: outdoor dry bulb temperature: 7℃, wet bulb temperature: 6℃, evaporator water inlet temperature: 40℃, water outlet temperature: 45℃
Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving
Small Air Cooled Chiller Unit
Specifications
Small air cooled chiller unit
Separate structure
Quiet operation
Easy installation
Automatic control
Small air cooled chiller unit
Energy-saving, air-cooled heat pump system units are an economical way to provide a reliable supply of hot and cold water. Highly efficient and compact since no cooling tower is required, they are also suitable for office building air-conditioning. These high-end models provide an answer to a variety of air-conditioning requirements.
Feature
Separate structure: Each type has complete models.
Quiet operation: Low-noise vortex compressor and low-speed cooling fan enabling quiet operation of the entire unit.
Easy installation: Factory completed internal wiring and refrigerant filling, and ex-factory strict testing; ready to use in the site once the power is switched on and the cooling water pipe connected.
Automatic control: The control cabinet containing all basic electric protection
devices, including electromagnetic switch, relay, over-current protector, and etc.
Parameter
Parameter List of Small Wind Cold Hot Water Unit
Note : 1. Nominal cooling conditions: condenser air inlet dry bulb temperature: 35℃, wet bulb temperature: 24℃, evaporator water inlet temperature: 12℃, water outlet temperature: 7℃
2. Nominal heatling conditions: outdoor dry bulb temperature: 7℃, wet bulb temperature: 6℃, evaporator water inlet temperature: 40℃, water outlet temperature: 45℃
Save & Reliable, Efficient & Environmental, Greative & Technoligical, Precise & Improving
RichScan
Thank you for your attention!
RichScan
Learn more!